CONTREX M-Traverse User Manual

Page 156

Advertising
background image

5 - 9

however, you can modify Control Parameter values with
operational data that is unique to your system.

Performance Monitoring

Tach
Lead Position
Follower Position
Follower Engineering Units
Product Rate
Position Error

Position Error

See Appendix C; MV-49.

PPR Follower

See Appendix C; CP-18.

Process Ratio

See Appendix C; MV-86.

Product Rate

See Appendix C; MV-46.

Profile Ratio

See Appendix C; MV-87.

Tach

See Appendix C; MV-40.

Traverse Length 1,2,3,4

See Appendix C; CP-02, 04, 06, 08.

Tuning

Tuning stabilizes speed error differences between the
setpoint and feedback.

Ring Kits

Ring Kits are flange motor mounted sensors that measure
the pulses per revolution (PPR) of the motor shaft.

Resume Enable

See Appendix C; CP-32.

RPM Feedback

The operating speed of the Follower.

RPM Lead

The operating speed of the Lead.

Run

The Run discrete input initiates the follower profiling
function. Run can be activated when the M–Traverse is in
F–Stop, however Run cannot be activated when the M–
Traverse is in Jog, Home Seek or Home Return.

Scaling

Scaling Control Parameters supply the M–Traverse with
the information that it needs to calculate the ratio of
Follower Lines to Lead Lines, using Engineering Units.

Serial Communications

The M–Traverse can interface with a host computer

Advertising