Cp-31 home offset – CONTREX M-Traverse User Manual

Page 169

Advertising
background image

5 - 22

CP-31

HOME OFFSET

The Home Offset (CP-31) parameter allows you to offset the “Home” position and relocate it
somewhere other than the sensor.

If CP-24 is set at “1” (edge based), measure the distance from the sensor to the desired position
of “Home”. Enter that E.U. amount in CP-31.

Sensor

DIRECTION

OF WIND

Home

Edge Based

Home Offset

(CP-31)

FOLLOWER

LEAD

If CP-24 is set at “2” (center based), measure the distance from the sensor to the center. Enter
that E.U. amount in CP-31. The M-Traverse will make a transparent, internal calculation and
position “Home” at a distance that is CP-31 minus 1/2 of the traverse length. The position of
“Home” will change to correspond with any changes in the traverse length.

Sensor

LINE FLOW

FOLLOWER

LEAD

Home

C

L

Center Based

Home Offset

(CP-31)

NOTE: Since the “Home” position calculations are dependent on the Traverse Length param-

eter (CP-02, CP-14, CP-06, CP-08) and the Engineering Units parameter (CP-15),
those values must have already been entered prior to entering a value in CP-31).