Appendix b: formulas, Appendix b: formulas -13 – CONTREX M-Traverse User Manual

Page 160

Advertising
background image

5 - 13

APPENDIX B: FORMULAS

Use the following formulas to calculate Tach (MV-40)

and E.U. setpointing (MV-84, MV-86).

M-TRAVERSE FORMULAS

Tach and Engineering

Feedback
Velocity (RPMs)

Feedback Frequency

(MV-42)

X

60

PPR Follower

(CP-18)

Follower
Profile
Length
(encoder lines)

Process
Ratio

Setpoint

(CP-01)

X

Follower Lines/ E.U.

(CP-17)

E.U.

(CP-15)

Lead PPR Reel

(CP-16)

(MV-40)

(MV-86)

(MV-84)

Follower Lines/E.U.

(CP-17)

E.U.

(CP-15)

Traverse Length

(CP-02)

X