CONTREX M-Traverse User Manual

Page 171

Advertising
background image

5 - 24

CP-37

FORWARD LIMIT FORMAT

Use the Forward Limit Format (CP-37) parameter to determine how the Forward Limit will
function during “Run”. If you set CP-37 to "1", then the M–Traverse will engage “F-Stop” when
the Forward Limit is encountered during “Run”. However, if you want the M–Traverse to
terminate the Constant Pitch Plateau, decelerate to zero speed, process the Forward End Dwell
and then begin the reverse profile back to home when the Forward Limit is encountered, then set
CP-37 to "2".

MV-40 TACH (FEEDBACK VELOCITY)

Tach is the feedback (Follower) displayed in RPMs. The feedback is read by the M-Traverse
every 250 microseconds. The readings are summed, averaged and then displayed every 250
milliseconds.

MV-41 LEAD FREQUENCY

The Lead Frequency displays the frequency of the Lead Frequency Input (J3, pin 3, 4, 5) in
hertz (pulses per second). MV-41 is averaged; it is the 250 millisecond frequency calculation
prior to the display update.

MV-42 FEEDBACK FREQUENCY

The Feedback Frequency displays the frequency of the Feedback Frequency Input (J3, pin 7, 8,
9) in hertz (pulses per second). MV-42 is averaged; it is the 250 millisecond frequency
calculation prior to the display update.

MV-43 LEAD POSITION

The Lead Position displays the distance of the Lead relative to the beginning of the profile. This
value is displayed in encoder lines.

MV-44 FOLLOWER POSITION

The Follower Position displays the distance of the Follower relative to the “Home” position. This
value is displayed in encoder lines.

MV-45 FOLLOWER POSITION - E.U.s

The Follower Position - E.U.s parameter converts the Follower Position (CP-44) into Engineering
Units.

Advertising