CONTREX M-Traverse User Manual

Page 19

Advertising
background image

2 - 4

The Isolator Voltage jumper (J3) is located on the Power Board (see Figure 2-2). It
configures the isolated analog output for either voltage that is ranged by an internal +15
volt reference or for voltage that is auto-ranged by the voltage level of the motor drive.
The auto-range voltage position is the default configuration for the Isolator Voltage
jumper.

NOTE: In most cases, the default configuration will be appropriate for your application

and it will not be necessary to re-configure.

If the motor drive does not have an external voltage reference, re-configure the Isolator
Voltage by moving the jumper from the default auto-range voltage position (1) to the
internal +15 volt reference position (2).

Figure 2-2 Power Board / Isolator Jumper

115

Auto Range
Position (default)

Internal Reference
Position

2 1