Appendix d: continued – CONTREX M-Traverse User Manual

Page 184

Advertising
background image

5 - 37

APPENDIX D: CONTINUED

USER

CODE DESCRIPTION

MIN

MAX DEFAULT

RECORD

UNITS

CP-61

Jog Setpoint

0

30000

50

RPM

CP-62

Direct Analog Command -4095

4095

0

DAC Bits

CP-65

Gain

0

30000

3000

N/A

CP-66

Integral

0

30000

1

N/A

CP-70

Device Address

1

32

1

N/A

CP-71

Baud Rate

1

6

6

Coded

CP-72

Character Format

1

3

2

Coded

CP-73

Control Mask

0

3

0

Coded

CP-79

Keypad Lockout Mask

1

2

1

Coded

CP-90

Output A Segment

1

3

1

Coded

CP-91

Output A Direction

1

3

1

Coded

CP-92

Output A Polarity

0

1

0

Coded

CP-93

Output B Segment

1

3

1

Coded

CP-94

Output B Direction

1

3

1

Coded

CP-95

Output B Polarity

0

1

0

Coded

Advertising