5 - 25

MV-46 PRODUCT RATE

The M-Traverse calculates the cycle time for the last completed profile (in each direction) and
uses this to determine the Product Rate in profiles (layers) per minute.

MV-47 DAC OUTPUT

The DAC Output displays the present level of the analog speed command output to the motor
drive. The DAC output displays in DAC bits. A value of 4095 indicates a 100% positive output
and a value of -4095 indicates a 100% negative output.

MV-48 TRIM OUTPUT

The Trim Output is the calculated output of the compensation algorithm (gain plus integral). This
value is displays in DAC bits. A value of 4095 indicates a 100% positive output and a value of -
4095 indicates a 100% negative output.

MV-49 POSITION ERROR

The Position Error displays the difference between the current Follower position and the
commanded Follower position. It displays in Follower encoder lines. A positive value indicates
that the Follower is behind the commanded position (lagging) and a negative value indicates that
the Follower is ahead of the commanded position (leading)

MV-50 KEYPAD ERROR

If a Control Parameter entry has been rejected, Keypad Errors will display the reason that it was
rejected. The digit that displays a number “1” is the error. In the example below, “Value Exceeds
Maximum Limit” is the error.

Invalid Code Parameter

Value Exceeds Maximum Limit

Value Below Minimum Limit

Keypad Lockout Enabled

Lockout During Run State or Entry Timeout

Not Used