Measuring wear on the wire

In order to gauge whether the wire is worn

circularly, it should be measured periodically

(e.g. every 2 hours)

When measuring the wire determine the

conicity (left-hand illustration) and the run-out

(right-hand illustration). Dimension deviations

should not exceed 0.2 mm.

Countermeasures in the event of a
flattened wire

If it is determined that the wire is worn flat or

non-circularly, immediate action must be

taken:

Turn the wire to a greater degree so that the

beads are moved spirally into the concrete

during cutting. This forced turn makes the

beads round once more.

In addition, the cutting pressure must be

reduced, especially with short wire contact

lengths.