1 flooded suction – Nova-Tech LMI Series AA-B-C-E-J-P Metering Pumps User Manual

Page 11

Advertising
background image

11

4.2.1 Flooded Suction

The pump is mounted at the base of the storage tank. This instal-

lation is the most trouble-free , and is recommended for very low

outputs, solutions that gasify, and high-viscosity solutions. Since

the suction tubing is filled with solution, priming is accomplished

quickly and the chance of losing prime is reduced.

When pumping downhill or into low or no pressure system, a

back pressure/anti-syphon device should be installed to prevent

overpumping or syphoning.

Although popular for all solutions, LMI recommends flooded

suction installations for all high-viscosity fluid applications.

Injection

Check

Valve

LMI Pump

Pump

Stand

Polymer

(Polyelectrolyte)

Drum

Vent

CORRECT

INCORRECT

LMI

35 Gallon

Solution

Tank

Tee

Avoid this type of false flooded suction.

Injection

Check Valve

CAUTION

!

CORRECT

Barrel Cradle