Pump models equipped with high-viscosity liquid ends are not

equipped with foot valves. Flooded suction is recommended. A 1/2"

NPT connector is included for flooded suction installations.

The ceramic weight, when installed, positions the foot valve in a

vertical position.

1. Attach the foot valve to one end of the suction tubing (see

Tubing Connections, Section 4.3).

2. Slide the ceramic weight over the tubing end until it contacts

the top of the foot valve coupling nut.

3. Place foot valve and tubing into the solution tank. Check that

the foot valve is vertical and approximately 2 inches (50 mm)

from the bottom of the tank or drum (see illustration). Connect

the other end of the tubing to the suction side of the pump

head (bottom side) (see Tubing Connections, Section 4.3).

Proper Foot Valve Position

LMI

Pump

Use Ceramic

Weight

Foot Valve

Must Remain

Vertical

Foot Valve

Tilted Sideways WILL NOT PRIME

INCORRECT

2.0 in. (50 mm)

for Sediment Accumulation

CORRECT

LMI

Pump

4.7

Foot Valve/Suction Tubing Installation

The Foot Valve acts as a check valve to keep the pump primed

in suction lift applications.
The foot valve is designed to be submersed in the solution tank

or drum and must sit in a vertical position at the bottom. Position

approximately 2 inches (50 mm) off the bottom if the tank or

drum contains sediment.