6.3

Start-Up/Priming without Multi-Function Valve

Read this entire section completely before proceeding.

When all precautionary steps have been taken, the pump is

mounted, and the tubing is securely attached, you may now

prime the pump.

1. Plug in or switch on the pump.

2. While the pump is running, set the speed knob at 80% and

the stroke knob at 100%.

If the pump is equipped with pressure control, turn fully

clockwise .

3. The suction tubing should begin to fill with solution from

the tank.

4. Once the solution begins to exit the pump head on the discharge

side, SHUT THE PUMP OFF. (If pump is not equipped

with an on/off switch, disconnect the power cord).

5. The pump is now primed.

6. Proceed to output adjustment, Section 6.4.
Ifthepumpdoesnotself-prime,removethefittingonthedis-

chargesideofthepumphead.Removetheballandpourwater

orsolutionintotheportuntiltheheadisfilled.Replacevalve,

thenfollowstartup/primingsteps.

Start-Up/Priming for AutoPrime™ Heads

Read this entire section completely before proceeding.

When all precautionary steps have been taken, the pump is

mounted, and the tubing is securely attached, you may prime

the pump.

1. Plug in or switch on the pump.

2. While the pump is running, set the speed knob and the stroke

knob at 100%.

3. The suction tubing should begin to fill with solution from

the tank as the AutoPrime™ valve purges air from the pump

head.

4. Once the solution begins to exit the pump head through both

the discharge valve and the AutoPrime™ valve, SHUT

THE PUMP OFF.

5. The pump is now primed.

6. Proceed to output adjustment, Section 6.4.

CAUTION

!