0 epu resistance chart – Nova-Tech LMI Series AA-B-C-E-J-P Metering Pumps User Manual

Page 44

Advertising
background image

12.0 EPU Resistance Chart

* Let pump cool down completely before checking resistance. EPU checked

within 10 hours of operation can increase coil resistance reading as much
as 20%.

NOTES:
1. Pumps with serial numbers

LOWER than: 960113429

2. Pumps with serial numbers

HIGHER than: 960113429

Pump Series

Voltage

Coil Resistance

(Ohms)

@ 20

o

C (68

o

F)*

PW4, PW5, PW6

P04, P05, P06

115 VAC

76 - 87

P14, P15 P16

230 VAC

307 - 353

P74, P75, P76
(see Note 1)

P02, P03

115 VAC

152 - 176

P12, P13

230 VAC

583 - 671

(see Note 2)
AA14, AA74, AA94

115 VAC

76- 87

AA15, AA75, AA95

230 VAC

291- 335

AA16, AA76, AA96
AA17, AA77, AA97
P02, P03

P12, P13
J54D, J55D, J56D

12 VDC

1.1 - 1.3

E70, E71, E72, E73, E74

115 VAC

22.8 - 26.2

230 VAC

91 - 105

B11, B12, B13, B14

115 VAC

43 - 49

B71, B72, B73, B74,

230 VAC

167 - 193

B91, B92, B93, B84
C10, C11, C12, C13, C14

115 VAC

22.8 - 26.2

C70, C71, C72, C73, C74

230 VAC

91 - 105

C90, C91, C92, C93, C94
C76, C77, C78

115 VAC

14.4 - 16.6

230 VAC

57.7 - 66.3

201 Ivyland Road

Ivyland, PA 18974

TEL: (215) 293-0401

FAX: (215) 293-0445

http://www.lmipumps.com

© 2001 Milton Roy Company - All Rights Reserved
Printed in USA
Specifications subject to change without notice.

Liquifram, Liquitron, Micropace, and Pro Pac are trademarks

of Milton Roy Company, Teflon is a registered trademark of

E. I. du Pont de Nemours & Co., Inc.

Advertising