Liquifram

™

Stroke Setting Chart

Pump Series

Stroke Knob Setting

All AA, B, J, P Series

C10, C11, C12, C70, C71, C72, C76,

90%

C90, C91, C92, E70, E71, E72

C78

50%

C13, C14, C73, C74, C77,

C93, C94, E73, E74

70%

*

Liquifram

™

on M Series pumps only, must be bottomed completely (turned

all the way in).

Do Not Use Straight Edge

.

6. Grasp the outer edge of the Liquifram

™

and adjust by screwing

it in or out so that the center of the Liquifram

™

is flush with

the outside of the spacer edge (see illustration below).

7. Once the Liquifram

™

is properly positioned, remount the

pump head to the spacer using the four (4) screws. Tighten

in a criss-cross pattern. After one week of operation, recheck

the screws and tighten if necessary.