Read steps 1 and 2 below before proceeding.

1. Be sure the Injection Check Valve is properly installed and is

operating. If a shut off valve has been installed downstream

of the Injection Valve, it should be closed.



Be sure your relief tubing is connected to your multi-function

valve and runs back to your solution drum or tank.

2. 1/4 turn the black knob on the valve. The discharge line is

now depressurized. Keep valve open until solution drains

back down the discharge tubing into solution drum or tank.

Then 1/4 turn knob to normal position.

9.2

Liquifram™ (Diaphragm) Replacement



ALWAYS wear protective clothing, face shield, safety glasses

and gloves when working near or performing any maintenance

or replacement on your pump. See MSDS information from

solution supplier for additional precautions.

LMI metering pumps are designed for trouble-free operation,

yet routine maintenance of elastomeric parts is essential for

optimum performance. This involves replacing the Liquifram

,

cartridge valves or seal rings/valve balls, multi-function valve cap

assemblies and the injection check valve spring. LMI recommends

replacing these parts at least once a year; however, frequency

will depend on your particular application.
When replacing the Liquifram

and the cartridge valves or seal

rings/valve balls, the injection check valve spring should

also be replaced (see next Section 9.3). A Spare Parts Kit

(SP-#) or RPM Pro Pac

kit containing these parts may be

obtained from your local distributor.

Replacing the Liquifram™:

1. Carefully depressurize, drain, and disconnect the discharge

line (see Section 8.1 in this manual). Place the Foot Valve

into a container of water or other neutralizing solution. Turn

the pump on to flush the head assembly. Once the pump head

has been flushed, lift the Foot Valve out of the solution and

continue to pump air into the pump head until the pump head

is purged of water or neutralizing solution.