0 troubleshooting – Nova-Tech LMI Series AA-B-C-E-J-P Metering Pumps User Manual

Page 40

Advertising
background image

40

PROBLEM

POSSIBLE CAUSE

Pump Will Not Prime

1.

Pump not turned on or plugged in.

2.

Output dials not set properly.

3.

Foot Valve not in vertical position on

bottom of tank.

4.

Pump suction lift too high.

5. Suction tubing is curved or coiled in

tank.

6.

Fittings are over tightened.

7.

Air trap in suction valve tubing.

8.

Too much pressure at discharge. (Pumps

without multi-function valve.)

Pump Loses Prime

1.

Solution container ran dry.

2. Foot Valve is not in a vertical position

on the bottom of the tank.

3.

Pump suction lift is too high.

4. Suction tubing is curved or coiled in

tank.

5.

Fittings are over tightened.

6. Air trap in suction valve tubing.

7.

Air leak on suction side.

11.0 Troubleshooting