4 multi-function valves, 1 three function valve (3-fv), 2 four function valve (4-fv) – Nova-Tech LMI Series AA-B-C-E-J-P Metering Pumps User Manual

Page 16

Advertising
background image

16

4.4

Multi-Function Valves

Your pump may be equipped with one of the following multi-

function valves: 3-FV, 4-FV, or standard discharge valve. If your

pump is not equipped with a multi-function valve and you feel it

is needed in your application, it can be purchased as an accessory.

Contact your local LMI stocking distributor.

4.4.1

Three Function Valve (3-FV)

1. Pressure Relief

If the discharge line is over pressurized, the valve opens

sending solution back to the supply tank.

2. Line Depressurization

Opening the relief knob provides line drain back to the sup-

ply tank.

3. Priming Aid

Opening the relief knob assists in priming the pump by

venting the discharge line to the atmosphere.

4.4.2

Four Function Valve (4-FV)

1. Pressure Relief

If the discharge line is over pressurized, the valve opens

sending solution back to the supply tank.

2. Line Depressurization

Opening the relief knob provides line drain back to the sup-

ply tank.

3. Anti-Syphon

Prevents syphoning when pumping solution downhill or into

a vacuum.

4. Back Pressure

Supplies approximately 25 psi back pressure to prevent

overpumping when little or no system back pressure is

present.

Advertising