Nova-Tech LMI Series AA-B-C-E-J-P Metering Pumps User Manual

Page 24

Advertising
background image

24

CAUTION

!

6.2

Start-Up/Priming for Pump Supplied

with Multi-Function Valve



Read this entire section completely before proceeding.

When all precautionary steps have been taken, the pump is

mounted, and the tubing is securely attached, you may now start

priming the pump.

1. Plug in or switch the pump on.

2. While the pump is running, set the speed knob at 80% and

the stroke knob at 100%.

Ifthepumpisequippedwithpressurecontrol,turnfullyclock-

wise.

3. 1/4 turn open the relief side (black knob) of the multi-func-

tion valve.

4. The suction tubing should begin to fill with solution from

the tank.

5. A small amount of solution will begin to discharge out the

return line of the multi-function valve. Once this happens,

1/4 turn or release the knob and SHUT THE PUMP OFF.

(If pump is not equipped with an on/off switch, disconnect

the power cord.)

6. The pump is now primed.

7. Proceed to output adjustment, Section 6.4.

Ifthepumpdoesnotself-prime,removethemulti-functionvalve

onthedischargesideofthepumphead.Removethecheckvalve

andpourwaterorsolutionintotheportuntiltheheadisfilled.

Replacevalve,thenfollowstartup/primingsteps.