Nova-Tech LMI Series AA-B-C-E-J-P Metering Pumps User Manual

Page 34

Advertising
background image

34

CAUTION

!

IftheliquidcannotbepumpedduetoLiquifram

™

rupture

usingprotectiveclothing,glovesandfaceshield,carefully

disconnectthesuctionanddischargetubing.Removethe

fourscrewstotheheadandimmersetheheadinwateror

otherneutralizingsolution.

2. Start the pump. While running, set the stroke knob to zero

and turn the pump off.

SeeSection10.0forproperzero

.

3. With the unit off, unscrew the Liquifram

™

by carefully

grasping the outer edge and turning it counter-clockwise

. Discard old Liquifram

™

. Remove the Liquifram

™

disk

if so equipped (located behind the Liquifram

™

) and check

that the size code matches the size code on the replacement

Liquifram

™

(see illustration).

4. Reinstall the disk so the alignment pin on the disk (if pres-

ent) seats in the recessed hole in the EPU.

Be careful not to scratch the Teflon

®

face of the new Liquifram

™

.

5. Start the pump and turn the stroke knob to the setting indi-

cated on the following Stroke Setting Chart which matches

the pump series number located on the pump dataplate. With

the pump stroking (running), screw on the new Liquifram

™

clockwise until the center begins to buckle inwards. Stop

the pump.

For Series AA, J, & P

For Series B, C, & E

Advertising