Nova-Tech LMI Series AA-B-C-E-J-P Metering Pumps User Manual

Page 34

Advertising
background image

34

CAUTION

!

IftheliquidcannotbepumpedduetoLiquifram

rupture

usingprotectiveclothing,glovesandfaceshield,carefully

disconnectthesuctionanddischargetubing.Removethe

fourscrewstotheheadandimmersetheheadinwateror

otherneutralizingsolution.

2. Start the pump. While running, set the stroke knob to zero

and turn the pump off.

SeeSection10.0forproperzero

.

3. With the unit off, unscrew the Liquifram

by carefully

grasping the outer edge and turning it counter-clockwise

. Discard old Liquifram

. Remove the Liquifram

disk

if so equipped (located behind the Liquifram

) and check

that the size code matches the size code on the replacement

Liquifram

(see illustration).

4. Reinstall the disk so the alignment pin on the disk (if pres-

ent) seats in the recessed hole in the EPU.

Be careful not to scratch the Teflon

®

face of the new Liquifram

.

5. Start the pump and turn the stroke knob to the setting indi-

cated on the following Stroke Setting Chart which matches

the pump series number located on the pump dataplate. With

the pump stroking (running), screw on the new Liquifram

clockwise until the center begins to buckle inwards. Stop

the pump.

For Series AA, J, & P

For Series B, C, & E