4.3

Tubing Connections

1. Insert tubing through Coupling Nut—Tubing should enter the smaller end of the

Coupling Nut first, orienting the larger opening of the Coupling Nut toward the

tubing end.

2a. For 1/4” OD tubing: Position the Female Ferrule so that 1/4” to 3/8” (5-10 mm) of

tubing protrudes from the Female Ferrule. Orient the raised collar of the Ferrule

toward the Coupling Nut (reference FIGURE 1).

2b. For 3/8” or 1/2” OD tubing: Position a Female Ferrule about one inch (25 mm)

from end of tubing. Orient the raised collar of the Female Ferrule toward the

Coupling Nut. Then, insert the Male Ferrule onto the end of the tube, pushing

the tube into the bottom of the groove in the Male Ferrule. Then slide the Female

Ferrule down the tubing and with your fingers, press tightly into the Male Ferrule

(reference FIGURE 2).

3. Firmly hand tighten the Coupling Nut onto the fitting. Note: Tightening with pliers

may cause the Ferrules to break.

A.

USE ONLY LMI TUBING—ALWAYS use LMI supplied

tubing with your pump, as the tubing is specifically designed for

use with the pump fittings.

B. DONOTUSECLEARVINYLTUBINGONTHEDISCHARGESIDEOF

THEPUMP. The pressure created by the pump can rupture vinyl tubing.

C. Before installation, all tubing must be cut with a clean square end.

D. Valve and head connections from the factory are capped or plugged to

retain pre-prime water. Remove and discard these caps or plugs before

connecting tubing.

 DONOTUSEPLIERSORPIPEWRENCHONCOUPLINGNUTS

ORFITTINGS.

 DONOTREUSEFERRULES—USEONLYNEWFERRULES.

(5-10 mm)

1/4" - 3/8"

1/4" O.D. or

3x6mm Tubing

Ferrule-

Female

Coupling Nut

Fitting

O-Ring

3/8" O.D. or

6x8mm Tubing

1/2" O.D. or

9x12mm Tubing

Ferrule-

Female

Coupling Nut

Fitting

O-Ring

Ferrule-

Male

FIGURE 1

FIGURE 2

CAUTION

!