Other data string customization – Fairbanks FB3000 Kernel Program Operators Manual User Manual

Page 24

Advertising
background image

Section 4: Input/ Output (I/O)

04/12

24

51147 Rev. 3

4.2.9. Other Data String Customization

Window Name

Description

CONFIGURE OUTPUT

─

Settings Tab

RS232 COM Port Drop-down

– Selects COM Port with its settings.

Data Transmission Options*

─

Continuous

[transmission]

─

Demand

– Upon demand as a poll character is received

─

Auto

– A transmission is sent when requested or when the

transaction is completed.

─

To File

– The message is not transmitted, but written to a file instead.

─

Network

– Transmission via IP over a network.

Port Settings*

─

Baud Rate, Parity, Data Bits

and

Stop Bits.

─

Checksum

– Returns a confirmation of transmission message

between computers.

─

Delimited

– Transmits data in Comma Delimited Format.

─

Multicast

– Method of networking scale weight information to other

FB3000 instruments across a Network.

─

Map View

– Displays data in a memory mapped location.

The

Testapp.exe

,

located in the

Kernel folder

, is used to verify

memory mapped data,

─

Output to PC104

– Sends data to optional PC 104 Weight Controller

Card using the

20mA or 4-20mA outputs.

Software Hand Shaking

– A means to control data flow using software

functions for communication between two or more devices.

─

None

– Bits are sent to source computer constantly without waiting for

available receiving modem.

─

Both, Receive or Transmit

– Determines which computer(s) wait

to accept the message packets.

Advertising