Other data string customization, continued – Fairbanks FB3000 Kernel Program Operators Manual User Manual

Page 29

Advertising
background image

Section 4: Input/ Output (I/O)

04/12

29

51147 Rev. 3

4.2.9. Other Data String Customization, Continued

Window Name

Description

CONFIGURE OUTPUT,

CONTINUED

Status Codes Tab

Programs data bits for

Status Words A, B

and

C

within the

Fairbanks and Toledo data streams.

Status Word

is eight (8) bits long.

12.

Put the

Status Words

in the blank Data Entry Position.

13.

Press the

Loaded it

button.

Weights Tab

Programs specific values for the Weight Tokens.

Weighing Digits

– Programs the length of the weight data.

Typically

six or seven digits

in length.

Leading Zeros

– When checked, adds leading zeros to the

weight data.

Justification

– Right or left.

Decimal Point

– None, Floating, Fixed, Trailing.

Fixed Decimal Places –

Sets number of decimal places in

weight data string.

Test Weight

– A manual weight entry to test data output.

Polarity

– When checked, it places a polarity token in front of the

weight data item.

Positive Token

– (+), None or Space

Negative Token

– ( ), None or Space

Advertising