Other data string customization, continued – Fairbanks FB3000 Kernel Program Operators Manual User Manual

Page 27

Advertising
background image

Section 4: Input/ Output (I/O)

04/12

27

51147 Rev. 3

4.2.9. Other Data String Customization, Continued

Window Name

Description

CONFIGURE OUTPUT,

CONTINUED

─

Tokens Tab

Programs the various data string tokens, such as the

Motion

flag.

Tokens are setup for the data protocol requirements.

Wrappers

─

Poll

– Polling character for a demand output.

Applicable only to the Demand Mode.

─

Start –

The first character of a data string.

─

Stop

– The last character of a data string.

─

Block

– The character that separates the data fields.

Units –

The character(s) used to define the unit of measure in the data

string

─

Primary

– The main indicator unit of measure.

─

Secondary

– The alternate indicator unit of measure.

Mode –

The character(s) used to define the Weighing Mode in the

data string.

─

Gross

– Character(s) used to designate the gross weight.

─

Tare

–

Character(s) used to designate the tare weight.

─

Net

–

Character(s) used to designate the net weight.

Advertising