Appendix iii: data output, Remote display output, Configure output – Fairbanks FB3000 Kernel Program Operators Manual User Manual
Page 52

04/12
52
51146 Rev. 3
Appendix III: Data Output
REMOTE DISPLAY OUTPUT
Remote Display Data Format
<STX><4><0><SP/-><XXXXXX><ETX>
Note(s):
1. Characters denoted by
X
are characters 0-9.
2. Leading zeroes are suppressed.
3. Polarity indication for a positive value is a space (
SP
).
−−−−
Negative values are not transmitted.
4.
Identifier code <4><0> = Gross weight
.
−−−−
Transmission is Gross Only.
5. Transmission for the DEMAND Mode occurs when a carriage return
(CR) Hex
0D
is received.
CONFIGURE OUTPUT
Fairbanks Data Format
<STX><A><B><C><GGGGGG><TTTTTT><CR>
Note(s):
1. Characters denoted by
G
and
T
are characters 0-9.
2. Leading zeroes are suppressed.
3. Gross Weight Data =
G
Tare Weight Data =
T
Status Code (Word) A
Bit #
X00
X0
X
X.X
X.XX X.XXX
X.XXXX
X.XXXXX
0
0
1
0
1
0
1
0
1
1
0
0
1
1
0
0
1
1
2
0
0
0
0
1
1
1
1