Section 4: Input/ Output (I/O)

04/12

26

51147 Rev. 3


4.2.9. Other Data String Customization, Continued

Window Name

Description

CONFIGURE OUTPUT,

CONTINUED

─

[Port] Settings
Tab

Control Signals

─

DSR (Data Set Ready) –

A control signal that indicates the

device is ready to transmit data.

─

CTS (Clear To Send) –

A control signal used to notify the

device that it has line control.

─

Load Tab

Selects a preconfigured data protocol based on the scale manufacturer
selected.

─

Select this item first when configuring an output.

─

Press the

OK

button to load the data protocol selected.

DEFAULT DATA PROTOCOLS

Fairbanks

<STX><A><B><C><GGGGGG><TTTTTT><CR>

Toledo

<STX><A><B><C><GGGGGG><TTTTTT><CR>

Cardinal

<CR><P><WWWWWW><m><SP><U><SP><g><SP><SP><ETX>

Weightronix

< ><M><WWWWWW>< ><U><CR><LF>

Condec

<STX><P><WWWWWWW><U><G><M><CR>

** See

Appendix III

for more formatting information.

Advertising