4.2.9. Other Data String Customization, Continued
Window Name
Description
CONFIGURE OUTPUT,
CONTINUED
─
[Port] Settings
Tab
Control Signals
─
DSR (Data Set Ready) –
A control signal that indicates the
device is ready to transmit data.
─
CTS (Clear To Send) –
A control signal used to notify the
device that it has line control.
─
Load Tab
Selects a preconfigured data protocol based on the scale manufacturer
selected.
─
Select this item first when configuring an output.
─
Press the
OK
button to load the data protocol selected.
DEFAULT DATA PROTOCOLS
Fairbanks
<STX><A><B><C><GGGGGG><TTTTTT><CR>
Toledo
<STX><A><B><C><GGGGGG><TTTTTT><CR>
Cardinal
<CR><P><WWWWWW><m><SP><U><SP><g><SP><SP><ETX>
Weightronix
< ><M><WWWWWW>< ><U><CR><LF>
Condec
<STX><P><WWWWWWW><U><G><M><CR>