Build tab definitions, Com port connections – Fairbanks FB3000 Kernel Program Operators Manual User Manual
Page 57
Advertising
Appendix III: Data Output
04/12
57
51146 Rev. 3
Condec Continuous Data Format
<STX><P><WWWWWWW><U><G><M><CR>
Note(s):
1. P = Polarity
space = positive weight
- = negative weight
W = Displayed weight
U = Units
L = pounds
K = kilograms
G = Gross; N = Net
M = Motion
2. Leading zeros are suppressed.
Build Tab Definitions
Load Cell Status <L> This item, if included in the data output string, indicates if a
load cell(s) are indicating an error. If no error is present, a zero (0) will be present or
the character equivalent of the decimal number of load cell with an error will be
indicated. i.e. 1 = <SOH>, 28 = <FS>
COM Port Connections
CN 2: COM1
External COM3 and COM4