Appendix III: Data Output

04/12

57

51146 Rev. 3

Condec Continuous Data Format

<STX><P><WWWWWWW><U><G><M><CR>

Note(s):

1. P = Polarity

space = positive weight
- = negative weight
W = Displayed weight
U = Units
L = pounds
K = kilograms
G = Gross; N = Net
M = Motion

2. Leading zeros are suppressed.

Build Tab Definitions

Load Cell Status <L> This item, if included in the data output string, indicates if a
load cell(s) are indicating an error. If no error is present, a zero (0) will be present or
the character equivalent of the decimal number of load cell with an error will be
indicated. i.e. 1 = <SOH>, 28 = <FS>

COM Port Connections

CN 2: COM1

External COM3 and COM4