Appendix IV: IP Command Functions
Command Structure:
[Sender],[COMMAND],Command,[End][LF]
Where Sender is:
The Computer Name of the PC which is sending the command.
Where Command is:
Lowercase z =
Zeroes all scales.
Uppercase Z1, Z2, etc = Zero a specific scale.
Uppercase ZA or ZB = Zero ScaleA (1 to 4) or ScaleB (5 to 8)
Lowercase u =
Change units on all scales.
Uppercase U1, U2, etc. = Change units on a specific scale.
Uppercase UA or UB = Change units on ScaleA (1 to 4) or
ScaleB (5 to 8)
Poll Character (see Configured Output) sends configured output.
Where LF is: Line Feed
Example:
[Freds PC],[COMMAND],Z1,[End][LF]
i.e. – Freds PC is requesting Scale 1 to Zero.