Evolver Solventborne Robotic Atomizers - Atex

EUROPEAN ATEX DIRECTIVE 94/9/EC, ANNEX II, 1.0.6

The following instructions apply to equipment cov-

ered by certificate number Sira 05ATEX5127X:

1. The equipment may be used with flammable

gases and vapors with apparatus groups II and with

temperature class T6.

2. The equipment is only certified for use in ambi-

ent temperatures in the range +12.8

°C to +55°C and

should not be used outside this range.

3. Installation shall be carried out by suitably trained

personnel in accordance with the applicable code of

practice e.g. EN 60079-14:1997.

4. Inspection and maintenance of this equipment

shall be carried out by suitably trained personnel in

accordance with the applicable code of practice e.g.

EN 60079-17.

5. Repair of this equipment shall be carried out by

suitable trained personnel in accordance with the

applicable code of practice e.g. EN 60079-19.

6. Putting into service, use, assembling, and adjust-

ment of the equipment shall be fitted by suitably

trained personnel in accordance with the manufac-

turer's documentation.

Refer to the "Table of Contents" of this service

manual.

a. Installation

b. Operation

c. Maintenance

d. Parts Identification

7. Components to be incorporated into or used as

replacement parts of the equipment shall be fitted

by suitably trained personnel in accordance with the

manufacturer's documentation.

8. The certification of this equipment relies upon the

following materials used in its construction:

If the equipment is likely to come into contact with

aggressive substances, then it is the responsibility

of the user to take suitable precautions that prevent

it from being adversely affected, thus ensuring that

the type of protection provided by the equipment

is not compromised.

Aggressive substances: e.g. acidic liquids or

gases that may attack metals, or solvents that may

affect polymeric materials.

Suitable precautions: e.g. regular checks as part of

routine inspections or establishing from the material's

data sheets that it is resistant to specific chemicals.

Refer to "Specifications" in the "Introduction" sec-

tion:

a. All fluid passages contain stainless steel or

nylon fittings.

b. High voltage cascade is encapsulated with

a solvent resistant epoxy.

9. A recapitulation of the certification marking is de-

tailed in the "ATEX" section, on the next page, drawing

numbers: A10752, A10754, A10755, and A10915.

10. The characteristics of the equipment shall be

detailed e.g. electrical, pressure, and voltage pa-

rameters.

The manufacturer should note that, on being put

into service, the equipment must be accompanied

by a translation of the instructions in the language

or languages of the country in which the equipment

is to be used and by the instructions in the original

language.

AA-03-02.11