Evolver gun selection guide (cont.) – Ransburg Evolver Solvent Applicator 79190-XXXXXXXX User Manual

Page 15

Advertising
background image

Evolver Solventborne Robotic Atomizers - Introduction

10

EVOLVER GUN SELECTION GUIDE (Cont.)

Table FF = Cable & Tubing Manifold Configuration

00 = Gun Only (No cable or manifold)

23 = No Cable (English tubing manifold)

24 = No Cable (Metric tubing manifold)

For Use W/Power Supply Configuration 3 or 4:

English

Metric

01 = 25' Cable (one-piece cable)

12 = 7.6m Cable (one-piece cable)

02 = 50' Cable (one-piece cable)

13 = 15.2m Cable (one-piece cable)

03 = 75' Cable (one-piece cable)

14 = 22.9m Cable (one-piece cable)

04 = 100' Cable (one-piece cable)

15 = 30.5m Cable (one-piece cable)

05 = 15' Cable to Junction Box; 15' Cable to Robot

16 = 4.6m Robot to Junction Box; 4.6m Cable to Robot

06 = 40' Cable to Junction Box; 15' Cable to Robot

17 = 12.2m Cable to Junction Box; 4.6m Cable to Robot

07 = 60' Cable to Junction Box; 15' Cable to Robot

18 = 18.3m Cable to Junction Box; 4.6m Cable to Robot

08 = 75' Cable to Junction Box; 15' Cable to Robot

19 = 22.9m Cable to Junction Box; 4.6m Cable to Robot

09 = 25' Cable to Junction Box; 25' Cable to Robot

20 = 7.6m Cable to Junction Box; 7.6m Cable to Robot

10 = 50' Cable to Junction Box; 25' Cable to Robot

21 = 15.2m Cable to Junction Box; 7.6m Cable to Robot

11 = 75' Cable to Junction Box; 25' Cable to Robot

22 = 22.9m Cable to Junction Box; 7.6m Cable to Robot

For Use W/Power Supply Configuration 1 or 2:

English

Metric

31 = 25' Cable (one-piece cable)

51 = 7.6m Cable (one-piece cable)

32 = 50' Cable (one-piece cable)

52 = 15.2m Cable (one-piece cable)

33 = 75' Cable (one-piece cable)

53 = 22.9m Cable (one-piece cable)

34 = 100' Cable (one-piece cable)

54 = 30.5m Cable (one-piece cable)

35 = 15' Cable to Junction Box; 15' Cable to Robot

55 = 4.6m Cable to Junction Box; 4.6m Cable to Robot

36 = 40' Cable to Junction Box; 15' Cable to Robot

56= 12.2m Cable to Junction Box; 4.6m Cable to Robot

37 = 60' Cable to Junction Box; 15' Cable to Robot

57 = 18.3m Cable to Junction Box; 4.6m Cable to Robot

38 = 75' Cable to Junction Box; 15' Cable to Robot

58 = 22.9m Cable to Junction Box; 4.6m Cable to Robot

39 = 25' Cable to Junction Box; 25' Cable to Robot

59 = 7.6m Cable to Junction Box; 7.6m Cable to Robot

40 = 50' Cable to Junction Box; 25' Cable to Robot

60 = 15.2m Cable to Junction Box; 7.6m Cable to Robot

41 = 75' Cable to Junction Box; 25' Cable to Robot

61 = 22.9m Cable to Junction Box; 7.6m Cable to Robot

Table G = Power Supply Configuration

0 = No Power Supply

1 = A10406-01 Power Supply Enclosure with one MicroPak and one Discreet I/O Card

2 = A10406-01 Power Supply Enclosure with two MicroPaks and two Discreet I/O Cards

3 = One LECU5004-31 MicroPak (FM Approved)

4 = One LECU5004-11 MicroPak (Not FM Approved)

79190 - A B C D E FF

G

AA-03-02.11

Advertising