Electrostatic Voltage

Under no load conditions, the maximum voltage limit

for these spray guns is 100 kV. Some painting opera-

tions may require different voltage settings to obtain

optimum transfer efficiencies. If Faraday cage areas

are predominant on the item being painted, a lower

voltage setting would aid in coating these areas.

When not spraying, it is recommended to set back

voltage to 30-40 kV or off between target parts.

Sometimes, depending upon target carrier spac-

ing, higher setback voltages may be required. The

ramp-up time for the HP-404 cascade (0-100 kV) is

approximately 3 seconds.

The MicroPak voltage ramp-down works at a rate of

33 kV/sec.

>

If target distance is less than 8 inches, an

arc could occur.

W A R N I N G

!

>

If a 0 kV command is sent to the MicroPak,

a feedback fault will occur.

NOTE

Target Distance

The distance between the gun tip and the article being

painted should be 10-14 inches. Excessive distance

causes a waste of coating material and wrap back

(paint particles being deposited on the gun body or

the robot arm). At close distances the voltage at the

tip of the gun will be reduced, which decreases the

charging effect of the gun.