47
Evolver Solventborne Robotic Atomizers - Maintenance
9. Tighten the regulator bonnet [10] to the block as-
sembly [1] securely with the six (6) screws [11] in an
alternating 180
° method. Reinstall the tube.
10. To remove the complete regulator assembly from
the gun, remove the coiled tube [29] by removing the
tubing nut and ferrules [25], [26], and [27].
11. Remove the regulator assembly from the fluid
inlet fitting [13] by removing the nut and ferrules
[13], [14], and [15] and pull up and out.
12. Reinstall the coiled tube [29] as shown in Figure
15; one of the coils of the tube must be wrapped
around the cascade as shown. Re-attach the pilot
tube [39] to the regulator bonnet.
13. Reassemble the remainder in reverse order.
>
When replacing the needle seat, be
cautious so that the plastic threads are not
stripped by cross threading.
NOTE
AA-03-02.11