47

Evolver Solventborne Robotic Atomizers - Maintenance

9. Tighten the regulator bonnet [10] to the block as-

sembly [1] securely with the six (6) screws [11] in an

alternating 180

° method. Reinstall the tube.

10. To remove the complete regulator assembly from

the gun, remove the coiled tube [29] by removing the

tubing nut and ferrules [25], [26], and [27].

11. Remove the regulator assembly from the fluid

inlet fitting [13] by removing the nut and ferrules

[13], [14], and [15] and pull up and out.

12. Reinstall the coiled tube [29] as shown in Figure

15; one of the coils of the tube must be wrapped

around the cascade as shown. Re-attach the pilot

tube [39] to the regulator bonnet.

13. Reassemble the remainder in reverse order.

>

When replacing the needle seat, be

cautious so that the plastic threads are not

stripped by cross threading.

NOTE

AA-03-02.11