Evolver solventborne robotic atomizers - atex – Ransburg Evolver Solvent Applicator 79190-XXXXXXXX User Manual
Page 11
6
Evolver Solventborne Robotic Atomizers - Atex
Label A10755
Label A10752
Label A10915
Evolver 79190 ATEX Product Marking
Definitions
Ex Certificate Number: Sira 05 ATEX 5 127 X
Sira = Notified Body performing EC-type examina-
tion
05 = Year of certification
ATEX = Reference to ATEX Directive
5 = Protection Concept Code (code 5 is titled Encap-
sulation)
127 = Document serial number
X = Special conditions for safe use apply
Special conditions for safe use: The Evolver 79190
Series Automatic Atomizers shall only be used with
associated Micropak A10406 or LECU5004-31 Power
Supplies.
Product Marking
II 2 G
Ex = Specific marking of explosive protection
II = Equipment Group hazardous area charac-teris-
tics
2 = Equipment Category
G = Type of explosive atmosphere (gases, vapors,
or mists)
EEx 0.24mJ = The Evolver 79190 Series of automatic
atomizers are suitable for use in automatic spray-
ing installations complying with EN 50176 as they
are a Type A class with a discharge energy limit of
0.24mJ.
Label A10754
AA-03-02.11