Evolver Solventborne Robotic Atomizers - Safety

AREA

Tells where hazards
may occur.

HAZARD

Tells what the hazard is.

SAFEGUARDS

Tells how to avoid the hazard.

Electrical

Equipment

High voltage equipment is utilized.

Arcing in areas of flammable or

combustible materials may occur.

Personnel are exposed to high

voltage during operation and

maintenance.

Protection against inadvertent arc-

ing that may cause a fire or explosion

is lost if safety circuits are disabled

during operation.

Frequent power supply shutdown

indicates a problem in the system

which requires correction.

An electrical arc can ignite coating

materials and cause a fire or explo-

sion.

The power supply, optional remote control cabinet, and

all other electrical equipment must be located outside

Class I or II, Division 1 and 2 hazardous areas. Refer to

NFPA-33.

Turn the power supply OFF before working on the

equipment.

Test only in areas free of flammable or combustible

material.

Testing may require high voltage to be on, but only as

instructed.

Production should never be done with the safety cir-

cuits disabled.

Before turning the high voltage on, make sure no objects

are within the sparking distance.

Explosion Hazard/

Incompatible Materi-

als

Halogenated hydrocarbon solvents

for example: methylene chloride

and 1,1,1,-Trichlor-oethane are not

chemically compatible with the

aluminum that might be used in

many system components. The

chemical reaction caused by these

solvents reacting with aluminum

can become violent and lead to an

equipment explosion.

Aluminum is widely used in other spray application

equipment - such as material pumps, regulators, trig-

gering valves, etc. Halogenated hydrocarbon solvents

must never be used with aluminum equipment during

spraying, flushing, or cleaning. Read the label or data

sheet for the material you intend to spray. If in doubt as

to whether or not a coating or cleaning material is com-

patible, contact your material supplier. Any other type

of solvent may be used with aluminum equipment.

Toxic Substances

Certain material may be harmful if

inhaled, or if there is contact with

the skin.

Follow the requirements of the Material Safety Data

Sheet supplied by coating material manufacturer.

Adequate exhaust must be provided to keep the air free

of accumulations of toxic materials.

Use a mask or respirator whenever there is a chance of

inhaling sprayed materials. The mask must be compat-

ible with the material being spray-ed and its concentra-

tion. Equipment must be as prescribed by an industrial

hygienist or safety expert, and be NIOSH approved.

AA-03-02.11