Troubleshooting guide (cont.), Fluid system electrical – Ransburg Evolver Solvent Applicator 79190-XXXXXXXX User Manual

Page 57

Advertising
background image

52

Evolver Solventborne Robotic Atomizers - Maintenance

Note: To check for fluid leaks, it is easiest to first remove the gun from the test station and remove the shroud

from the gun. Then the gun can be remounted to the test station. Leak detector may be used at all appropri-

ate sources. Be certain to wipe off all residual solution using a non-conductive solvent such

as Naphtha.

TROUBLESHOOTING GUIDE (Cont.)

General Problem

Possible Causes

Corrective Action

Excessive Current or

Loss of High Voltage

1. Metallic particle alignment

in coiled tube

2. Fluid leaks inside

3. Fluid coil pin-holed

4. Exterior of gun contami-

nated

1. Start fluid flow before turning voltage on.

2. Repair/replace fittings and/or coiled fluid tube

as required.

3. Replace coil as required.

4. Clean with non-polar solvent.

Fluid System

Electrical

General Problem

Possible Causes

Corrective Action

No Electrostatics

Low kV, High µA Out-

put

Low kV, Low µA Out-

put

1. Cascade not functioning

1. Exterior of gun contaminat-

ed with conductive material

1. Cascade failure

1. Check low voltage cable and harness timing

mark positions. Correct as required.

2. Cascade bad. Replace as required.

3. Low voltage cable connections wrong at

MicroPak.

4. Low voltage cable bad. Replace as required.

1. Replace gun cover.

2. Clean exterior with a non-polar solvent.

1. Replace as required.

AA-03-02.11