Troubleshooting guide – Ransburg Evolver Solvent Applicator 79190-XXXXXXXX User Manual

Page 56

Advertising
background image

51

Evolver Solventborne Robotic Atomizers - Maintenance

TROUBLESHOOTING GUIDE

Note: A test station to bench test the applicator off-line will speed the Troubleshooting process.

General Problem

Possible Causes

Corrective Action

Fluid Does Not

Turn On

No Fan or Atomiza-

tion Air Pressure At

the Air Cap

1. Trigger pilot regulator has

not been set to a minimum

of 70 psig

2. The green air tube possibly

left disconnected during re-

assembly

3. Green tube leading from

the source to the gun

mounting plate is pinched or

broken

4. Piston seal within the gun

spray head is not in place

or there is an extremely

tight fit between the seal

and the cylinder wall

1. Low trigger pilot air pres-

sure (70 psi min. required)

2. Air tubes 79134-00 are not

installed properly.

3. Black or natural 3/8" OD

tube is cut or pinched

1. Increase to 70 psig minimum.

2. Reconnect tubing.

3. Check the tubing for kinks or damage. Re-

place if worn or damaged.

4a. Make sure that the seal is in the proper posi-

tion and/or lubricate with a small amount of

petroleum jelly.

4b. O-rings left out of small Ø tie rods.

4c. O-ring missing between mounting block and

upper manifold.

4d. O-ring missing between mounting block and

replaceable head.

1. Increase pressure.

2. Reinstall and tighten as required.

3. Examine, repair as required.

AA-03-02.11