Evolver Solventborne Robotic Atomizers - Maintenance

Low Voltage Cable Removal

(Refer to Figure 14)

1. Disconnect low voltage cable [2] from rear of power

supply. For A10406-XX power supply, disconnect

circular connector from receptacle on rear of power

supply. For LECU5004-XX power supply, disconnect

wires from connector J3 at rear of MicroPak.

2. Loosen retaining ring [5] (see Figure 10) and remove

applicator from robot wrist.

3. Using 3/16" Allen wrench, remove set screw [10].

4. Remove the low voltage cable [2] by pulling through

the robot arm and mounting plate.

5. To reinstall, insert power supply end of cable [2]

through mounting plate [3], pull through robot arm

and connect to junction box or power supply. For

connections to power supply, plug connector into re-

ceptacle (A10406-XX power supply) or connect wires

as shown in Figure 4 (LECU5004-XX power supply).

6. Align the timing mark of the plug on the appli-cator

end of the cable [2] with the mark on the mounting

plate [3] and tighten set screw [10].

FLUID REGULATOR

(When Equipped - See Figure 15)

1. Remove all pressures, both air and fluid from

the line leading to the spray gun.

2. Purge all fluid from the gun prior to performing

any service.

3. Remove one end of the tubing [39] from the fitting

[12]. Remove the six (6) screws [11].

4. Remove diaphragm assembly [10] and in-

spect it for wear or damage. Pay particular attention

to the air side, since it can be damaged by solvent

contact. Replace if necessary.

>

Once regulator bonnet [10] is re-moved,

diaphragm [2] will be loose and may fall

out.

NOTE

2

79008-XX

Low Voltage Cable, One-Piece, for LECU5004-XX Power Supply

1

2

A11353-XX

Low Voltage Cable, One-Piece, for A10406-XX Power Supply

1

2

A11355-XX

Low Voltage Cable, Junction, for A10406-XX Power Supply

1

3

79155-00

Robot Mounting Plate, English Fittings

1

3

A10975-00

Robot Mounting Plate, Metric Fittings

1

10

SSF-2052

Set Screw

1

Item #

LOW VOLTAGE CABLE REMOVAL - PARTS LIST (Figure 14)

Part #

Description

Qty

5. Use a 3/16" Allen wrench to unscrew the pop-

pet seat retainer. The tungsten carbide seat and

needle may pop out because of the spring force ap-

plied against them.

6. Inspect the needle and seat assembly [4] for

wear. If wear or damage is evident, replace. Replace

both needle and seat at the same time because they

are a matched set. Inspect o-ring (5) for damage,

replace as necessary.

7. Reassemble the fluid regulator by inserting the

spring [3], needle and seat [5] back into the regulator

block assembly. Be sure to lube o-ring. Secure the

needle/seat assembly by screwing the seat retainer

[4] into the regulator block assembly until a torque

of 8-10 lbs•in is obtained.

8. When replacing the diaphragm [2], remove the

screw [9] that holds both halves together. Inspect

o-ring [6] for damage. To reassemble, make sure that

the side is toward the lower support [8]. Reinstall

screw and tighten. Be careful not to over tighten. If

the diaphragm is inserted wrong, damage will occur.

Push the diaphragm assembly down in valve body

aligning the screw holes.

AA-03-02.11