Caution in handling – IAI America RCP2-BA7U User Manual

Page 14

Advertising
background image

8

Caution in Handling

1. Ensure use of the product in the specified conditions, environments

and ranges.

Not keeping this may cause a drop in the performance or even a malfunction of the product.

2. Do not attempt to handle or operate the product in a way that is not

described in the operating manual.

3. Use the products of IAI for the wiring between an actuator and a

controller.

4. Do not set speeds and accelerations/decelerations equal to or

greater than the respective ratings.

If the actuator is operated at a speed or acceleration/deceleration exceeding the allowable
value, abnormal noise or vibration, failure, or shorter life may result.

5. Keep the load moment within the allowable value.

If the actuator is operated under a load equal to or greater than the allowable load moment,

abnormal noise or vibration, failure, or shorter life may result.

6. Do not apply any liquid with temperature lower than the ambient

temperature of the installed actuator.

It may cause condensation inside the product, which may lead to malfunction.

7. Back and forth operation in a short distance may cause wear of

grease.

If the actuators are moved back and forth continuously over a short distance of 30 mm or
less, grease film may run out. As a guide, move the actuators back and forth repeatedly for

around 5 cycles over a distance of 50mm or more after every 5,000 to 10,000 cycles. Keep
using the actuators with the grease worn out may cause malfunction.

8. Make sure to attach the actuator properly by following this operating

manual.

Using the product with the actuator not being certainly retained or affixed may cause

abnormal noise, vibration, malfunction or shorten the product life. Turn the servo ON after

separating the slider. from the mechanical end.

9. Turn the servo ON after putting the actuator or rod away from the�

mechanical end.

Turning the servo ON near the mechanical end may disturb the magnetic pole phase

detection, and may cause the magnetic pole unconfirmed error or the excitation detection

error. Turn the servo ON after separating the slider, from the mechanical end.