IAI America RCP2-BA7U User Manual

Page 30

Advertising
background image

2. Installation

24

2.2 Installation and Storage • Preservation Environment

[1] Installation Environment

The actuator should be installed in a location other than those specified below.

In general, the installation environment should be one in which an operator can work without

protective gear.

Also provide sufficient work space required for maintenance inspection.

Where the actuator receives radiant heat from strong heat sources such as heat treatment

furnaces

Where the ambient temperature exceeds the range of 0 to 40�C

Where the temperature changes rapidly and condensation occurs

Where the relative humidity exceeds 85% RH

This actuator possesses the water durability of IP67 protection structure.

Where the actuator receives direct sunlight

Where the actuator is exposed to corrosive or combustible gases

Where the ambient air contains a large amount of powder dust, salt or iron (at level exceeding

what is normally expected in an assembly plant)

Where the actuator is subject to splashed oil (including oil mist or cutting fluid) or chemical

solutions

Where the actuator receives impact or vibration


If the actuator is used in any of the following locations, provide sufficient shielding measures:

Where noise generates due to static electricity, etc.

Where the actuator is subject to a strong electric or magnetic field

Where the actuator is subject to ultraviolet ray or radiation

[2] Storage � Preservation Environment

The storage and preservation environment should comply with the same standards as those for

the installation environment. In particular, when the machine is to be stored for a long time, pay

close attention to environmental conditions so that no dew condensation forms.

Unless specially specified, moisture absorbency protection is not included in the package when

the machine is delivered. In the case that the machine is to be stored and preserved in an

environment where dew condensation is anticipated, take the condensation preventive

measures from outside of the entire package, or directly after opening the package.

For storage and preservation temperature, the machine withstands temperatures up to 60�C for

a short time, but in the case of the storage and preservation period of 1 month or more, control

the temperature to 50�C or less.

Storage and preservation should be performed in the horizontal condition. In the case it is stored

in the packaged condition, follow the posture instruction if any displayed on the package.

Advertising