4. Maintenance Inspection

34

4. Maintenance Inspection

4.1 Inspection Items and Schedule

Follow the maintenance inspection schedule below.

It is assumed that the equipment is operating 8 hours per day.

If the equipment is running continuously night and day or otherwise running at a high operating rate,

inspect more often as needed.


External visual inspection Check interior

Greasing

Belt loosening

Start of work inspection

1 month inspection

6 month inspection

12 month inspection

Every 6 months

thereafter

Every 12 months

thereafter

* If the actuator are operated back and forth repeatedly over a distance of 30mm or less, the oil film

created by the grease may be broken. As a guide, move the actuators back and forth repeatedly for

around 5 cycles over a distance of 50mm or more after every 5,000 to 10,000 cycles. A layer of the

grease will recover.

4.2 External Visual Inspection

An external visual inspection should check the following things.

Main unit

Loose actuator mounting bolts, other loose items

Cables

Scratches, proper connections

Overall

Irregular noise, vibration

4.3 Cleaning

• Clean the exterior as needed.

• Wipe off dirt with a soft cloth.

• Do not use strong compressed air on the actuator as this may force dust into the crevices.

• Do not use petroleum-based solvent on plastic parts or painted surfaces.

• If the unit is badly soiled, apply a neutral detergent or alcohol to a soft cloth, and wipe gently.