Building your network system, 1 procedure – IAI America RCM-GW-PR User Manual
Page 102

96
PfofiBus Gateway
7. Building Your Network System
7.1 Procedure
The procedure to start a ProfiBus network using the gateway unit is explained below.
(1) Installation
Install the ProfiBus gateway unit, each axis controller and other necessary units in the
control panel.
(2) Wiring
Wire the gateway unit’s 24-V power supply and field network, and also wire for SIO
communication, etc. (Refer to Section 4.)
(3) Setting the axis number for each axis controller (Refer to 4.3.2 and 7.2.)
Setting the SIO baud rate for each axis controller (Refer to 7.2.)
(4) Setting the baud rate, node address and mode setting switch for the gateway unit
(Refer to 2.3 and 7.3.)
(5) Setting the node address and baud rate and assigning the master PLC address for the
ProfiBus master (Refer to 7.3 and 7.4.)
(6) Creating a controller position table
(7) Creating a PLC ladder sequence