CAUTION


Note on Connecting a PC or Teaching Pendant to the Gateway
Unit Grounded via the Positive Terminal of Its 24-V Power Supply



If the positive terminal of the gateway unit’s 24-V power supply is grounded, use a SIO converter as
shown below to connect a teaching pendant or PC to the gateway unit. In this case, do not connect the FG
of the SIO converter.









































Teaching pendant

PC, etc.

PC software

RS232 connection type
<Model number: RCM-101-MW>
USB connection type
<Model number: RCM-101-USB>
* The cables are supplied with the

PC software.

SIO converter (optional)
(with built-in terminal resistor)
Model number: RCB-TU-SIO-A (B)

Gateway unit

Do not
connect
the FG.

* One e-CON connector, one junction

and one terminal resistor are supplied
with each controller link cable.

e-CON connector (3-1473562-4 by AMP)

Junction (5-1473574-4 by AMP)

Terminal resistor
R = 220

Controller link cable
Model number: CB-RCB-CTL002

24-V power

supply