IAI America RCM-GW-PR User Manual

Page 58

Advertising
background image



52

PfofiBus Gateway

Signal type

Bit

Signal

name

Description Details

P

L

C

ou

tp

ut

In-position

band

24-bit

data

-

Set a 24-bit integer (unit: 0.01 mm) based on
hexadecimal notation.
Example) To specify +25.4 mm, set “0009ECH”

(“2540” in decimal notation).

(Notes)
z Set position data within the soft stroke limits.
z Specify the direction of push-motion operation using

DIR.

z Even if in-position band is not set, the setting of

parameter No. 10, “Default in-position band” will not
be applied.

6.3 (4)

Control

signal

b7

-

Cannot be used.

-

b6 DIR

Push direction specification
(0 = Home return direction,
1 = Opposite to home return direction)

6.3 (4)

b5

PUSH

Push-motion operation mode specification

6.3 (4)

b4

SON

Servo on command

6.2 (7)

b3

STP

Pause command

6.2 (5)

b2

HOME

Home return command

6.2 (8)

b1 CSTR

Start

command

6.2

(9)

b0 RES

Reset

command

6.2

(4)

PL

C

i

n

p

u

t

Status

signal

b7

EMGS

Emergency stop status

6.2 (2)

b6

PSFL

Missed work

6.3 (4)

b5

PWR

Controller ready

6.2 (1)

b4

SV

Ready (servo is on)

6.2 (7)

b3 MOVE

Moving

6.2

(6)

b2

HEND

Home return complete

6.2 (8)

b1 PEND

Positioning

complete

6.2

(10)

b0 ALM

Alarm

6.2

(3)

b7-b0

-

Cannot be used.

-

Current

position

data

24-bit

data

-

The current position data is output as a signed 24-bit
integer (unit: 0.01 mm) based on hexadecimal
notation.
Example) To specify +25.4 mm, set “0009ECH”

(“2540” in decimal notation).

A negative value is indicated by a 2’s complement,
which means that the most significant bit becomes “1.”

6.3 (4)

- b7-b0 -

Cannot

be

used.

-