IAI America RCM-GW-PR User Manual

Page 62

Advertising
background image



56

PfofiBus Gateway


Example of Address Configuration















































*1 The byte address Byte+ indicates a relative address from the initial byte address of the gateway.
*2 The numbers in parentheses ( ) indicate axis numbers on the SIO communication network.

Output from PLC

⇒ Gateway Unit

⇒ Input to each axis

Output from each axis

⇒ Gateway Unit

⇒ Input to PLC

Byte

address

Upper byte

Lower byte

Upper byte

Lower byte

Gateway control signal 0

Gateway control signal 1

Request command

Data 0

Data 1

Data 2

Data 3
Data 4

Data 5

Positioner operation axis (0) control signal

Positioner operation axis (1) control signal

Positioner operation axis (2) control signal

Positioner operation axis (3) control signal

Simple direct operation axis (4)*2 control signal

Simple direct operation axis (5) control signal






Simple direct operation axis (6) control signal






Simple direct operation axis (7) control signal


Gateway status signal 0

Gateway status signal 1

Response command

Data 0

Data 1

Data 2

Data 3

Data 4

Data 5

Fixed

area

2 bytes

6 bytes

Small mode

(64 bytes)

Middle mode

(128 bytes)

Large mode

(160 bytes)

Cannot be used.

Cannot be used.

2 bytes

8 bytes

Positioner operation axis (0) status signal

Positioner operation axis (1) status signal

Positioner operation axis (2) status signal

Positioner operation axis (3) status signal

Simple direct operation axis (4) status signal

Simple direct operation axis (5) status signal




Simple direct operation axis (6) status signal



Simple direct operation axis (7) status signal

Gateway
control
area

Command
I/O area

Command
I/O area

Axis control
area