Safety, Warnings – ZOLL SurePower Rev B Charger Station User Manual

Page 12

Advertising
background image

viii

www.zoll.com

9650-0535-01 Rev. B

Safety

The following sections provide important warnings and notices regarding the ZOLL SurePower
Charger Station
.

Warnings

Accidental sliding or drop of the SurePower Charger Station or battery may cause physical

injury. Operate the SurePower Charger Station on a stable surface and be careful when

carrying or moving the unit to avoid injury. Damaged batteries may expose users to a safety

hazard. Should the SurePower Charger Station or SurePower Battery Pack be dropped,

inspect and test the unit prior to further use following the procedures described in this

manual. Use caution when handling batteries with damaged cases.

Avoid prolonged exposure of the SurePower Charger Station or SurePower Battery Pack to

direct sunlight to minimize charger and battery heating and the damage that may occur from

exposure to ultraviolet light.

The SurePower Charger Station and ZOLL rechargable defibrillator batteries have been

tested against interference from radio frequency emissions typical of two-way radios used in

emergency service/public safety activities. Refer to Appendix A to determine recommended

operating distances from RF transmission equipment

.

Use only the AC cord supplied with the device. Failure to use the proper line cord could

result in excess leakage currents, EMC problems, and reduced safety.

Do not disassemble the SurePower Charger Station. A shock hazard exists. Refer all

problems to qualified personnel.

Do not place anything on top of or beneath the SurePower Charger Station, such as blankets

or cloths. Doing so may block the vents on the unit, preventing proper dissipation of heat

during operation.

Do not use the SurePower Charger Station unit stacked with other equipment.

Do not use a battery unless the charger’s Ready LED is lit and the Fault LED is off. Failure

to do so may result in the use of a fully depleted battery.

Use the SurePower Charger Station only in a well-ventilated area. Should a battery become

overheated, the battery can vent gas that is harmful and potentially explosive.

An insulation or ground failure in the SurePower Charger Station can result in dangerous

leakage currents. To avoid this, perform periodic inspection following the procedures

described in this manual.

Do not operate the SurePower Charger Station in the presence of flammable agents (such as

gasoline), oxygen-rich atmospheres, or flammable anesthetics. Using the device in the

presence of flammable agents can cause an explosion.

Do not immerse or set the SurePower Charger Station or SurePower Battery Pack in liquid.

Using the device near or within puddles of water may present a shock hazard to the operator,

patient, and nearby personnel.

A pinch hazard exists when installing a battery into a charging bay.

If the display indicators on a SurePower Battery Pack are not consistent with the indicators

on the SurePower Charger Station or ZOLL defibrillator, a fault condition may be present.

Remove the battery from service as soon as practical, and verify the correct operation of the

charger, defibrillator, and battery.

Do not use the SurePower Charger Station in environmental conditions that fall outside of

those specified in Chapter 6, “Product Specifications -- SurePower Charger Station.” Using

the SurePower Charger Station in environmental conditions that fall outside those described

in the product specifications can result in failure of the unit.

Do not use the SurePower Charger Station in the proximity of Electrosurgical Units (ESU).

Advertising