10-6

10. GENERAL SPECIFICATIONS

10.3

Optional Specifications

For F

OUNDATION

Fieldbus explosion protected type, see IM 01C22T02-01E.

For PROFIBUS PA explosion protected type, see IM 01C22T03-00E.

Item

Description

Code

Factory Mutual (FM)

CENELEC ATEX (KEMA) Intrinsically safe Approval

*2

Certificate: KEMA 02ATEX1030X

II 1G EEx ia IIC T4, Amb. Temp.: –40 to 60

Њ

C (–40 to 140

Њ

F)

Ui=30 V, Ii=165 mA, Pi=0.9 W, Ci=22.5 nF, Li=730

H

KS2

FM Intrinsically safe Approval

*1

Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1,

Groups E, F & G and Class III, Division 1 Hazardous Locations.

Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division. 2,

Groups E, F & G, and Class III, Division 1 Hazardous Locations.

Enclosure: “NEMA 4X”, Temp. Class: T4, Amb. Temp.: –40 to 60

Њ

C (–40 to 140

Њ

F)

Intrinsically Safe Apparatus Parameters

[Groups A, B, C, D, E, F and G]

Vmax=30 V, Imax=165 mA, Pmax=0.9 W, Ci=22.5 nF, Li=730

H

[Groups C, D, E, F and G]

Vmax=30 V, Imax=225 mA, Pmax=0.9 W, Ci=22.5 nF, Li=730

H

FS1

CENELEC ATEX (KEMA) Flameproof Approval

*2

Certificate: KEMA 02ATEX2148

II 2G EExd IIC T4, T5, T6

Amb. Temp.: T5; –40 to 80

Њ

C ( –40 to 176

Њ

F), T4 and T6; –40 to 75

Њ

C ( –40 to 167

Њ

F)

Max. process Temp.: T4; 120

Њ

C (248

Њ

F), T5; 100

Њ

C (212

Њ

F), T6; 85

Њ

C (185

Њ

F)

KF2

FM Explosionproof Approval

*1

Explosionproof for Class I, Division 1, Groups B, C and D

Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G

Hazardous (classified) locations, indoors and outdoors (NEMA 4X)

Temperature class: T6

Amb. Temp.: –40 to 60

Њ

C (–40 to 140

Њ

F)

FF1

FU1

Combined FF1 and FS1

*1

Combined KF2, KS2 and Type n

*2

Type n

II 3G Ex nL IIC T4, Amb. Temp.: –40 to 60

°

C (–40 to 140

°

F)

Ui=30 V DC, Ci=22.5 nF, Li=730

µ

H

Dust

II 1D maximum surface temperature T65

°

C (149

Њ

F) {Tamb.: 40

°

C (104

Њ

F)},

T85

°

C (185

Њ

F) {Tamb.: 60

°

C (140

Њ

F)}, T105

°

C (221

Њ

F) {Tamb.: 80

°

C (176

Њ

F)}

KU2

CENELEC ATEX

T1008-1.EPS

*1:

Applicable for Electrical connection code 2 and 7 (1/2 NPT female).

*2:

Applicable for Electrical connection code 2, 4, 7 and 9 (1/2 NPT and M20 female).