Yokogawa EJA110A User Manual

Page 71

Advertising
background image

IM 01C21B01-01E

10-7

10. GENERAL SPECIFICATIONS

Item

Description

Code

CSA Explosionproof Approval

*1

Certificate: 1089598

Explosionproof for Class I, Division 1, Groups B, C and D

Dustignitionproof for Class II/III, Division 1, Groups E, F and G

Division2 ‘SEALS NOT REQUIRED’ , Temp. Class: T4, T5, T6 Encl Type 4x

Max. Process Temp.: T4; 120

Њ

C (248

Њ

F), T5; 100

Њ

C (212

Њ

F), T6; 85

Њ

C (185

Њ

F)

Amb. Temp.: –40 to 80

Њ

C (–40 to 176

Њ

F)

Process Sealing Certification

Dual seal certified by CSA to the requirement of ANSI/ISA 12.27.01

No additional sealing required. Primary seal failure annunciation : at the zero adjust-

ment screw

CF1

Canadian Standards
Association (CSA)

CSA Intrinsically safe Approval

*1

Certificate: 1053843

Intrinsically Safe for Class I, Groups A, B, C and D Class II and III, Groups E, F and G

Nonincendive for Class I, Division 2, Groups A, B, C and D Class II, Division 2,

Groups F and G and Class III (not use Safety Barrier)

Encl Type 4x, Temp. Class: T4, Amb. Temp.: –40 to 60

Њ

C (–40 to 140

Њ

F)

Vmax=30 V, Imax=165 mA, Pmax=0.9 W, Ci=22.5 nF, Li=730

H

Process Sealing Certification

Dual seal certified by CSA to the requirement of ANSI/ISA 12.27.01

No additional sealing required. Primary seal failure annunciation : at the zero adjust-

ment screw

CS1

IECEx
Scheme

SU2

IECEx Intrinsically safe, type n and Flameproof Approval

*2

Intrinsically safe and type n

Certificate: IECEx KEM 06.0007X

Ex ia IIC T4, Ex nL IIC T4 Enclosure: IP67

Amb. Temp.: –40 to 60

Њ

C (–40 to 140

Њ

F), Max. Process Temp.: 120

Њ

C (248

Њ

F)

Electrical Parameters: [Ex ia] Ui=30 V, Ii=165 mA, Pi=0.9 W, Ci=22.5 nF, Li=730

H

[Ex nL] Ui=30 V, Ci=22.5 nF, Li=730

H

Flameproof

Certificate: IECEx KEM 06.0005

Ex d IIC T6...T4 Enclosure: IP67

Max.Process Temp.: T4;120

Њ

C (248

Њ

F), T5;100

Њ

C (212

Њ

F), T6; 85

Њ

C (185

Њ

F)

Amb.Temp.: –40 to 75

Њ

C (–40 to 167

Њ

F) for T4, –40 to 80

Њ

C (–40 to 176

Њ

F) for T5,

–40 to 75

Њ

C (–40 to 167

Њ

F) for T6

CU1

Combined CF1 and CS1

*1

T1008-2.EPS

*1:

Applicable for Electrical connection code 2 and 7 (1/2 NPT female).

*2:

Applicable for Electrical connection code 2, 4 and 7 (1/2 NPT and M20 female).

Advertising