2. HANDLING CAUTIONS

2.

HANDLING CAUTIONS

This chapter describes important cautions regarding
how to handle the transmitter. Read carefully before
using the transmitter.

The EJA-A Series pressure transmitters are thoroughly
tested at the factory before shipment. When the
transmitter is delivered, visually check them to make
sure that no damage occurred during ship-ment.

Also check that all transmitter mounting hardware
shown in Figure 2.1 is included. If the transmitter was
ordered without the mounting bracket or without the
process connector, the transmitter mounting hardware
is not included. After checking the transmitter, repack
it in the way it was delivered until installation.

Bolt

Process connector

Process connector
Gasket

U-bolt nut

U-bolt

Mounting bracket
(L type)

Transmitter mounting bolt

Mounting bracket
(Flat type)

F0201.EPS

Figure 2.1 Transmitter Mounting Hardware

2.1 Model and Specifications

Check

The model name and specifications are indicated on the
name plate attached to the case. If the reverse operat-
ing mode was ordered (reverse signal), ‘REVERSE’
will be inscribed in field *

1

; if square root display

mode was ordered, ‘SQRT’ is inscribed in field *

2

; if

square root output mode was ordered, ‘SQRT’ is
inscribed in field *

3.

F0202.EPS

: Refer to USER'S MANUAL

Figure 2.2 Name Plate

2.2 Unpacking

When moving the transmitter to the installation site,
keep it in its original packaging. Then, unpack the
transmitter there to avoid damage on the way.

2.3 Storage

The following precautions must be observed when
storing the instrument, especially for a long period.

(a) Select a storage area which meets the following

conditions:
• It is not exposed to rain or water.
• It suffers minimum vibration and shock.
• It has an ambient temperature and relative

humidity within the following ranges.

Ambient temperature:

–40 to 85

°

C without integral indicator

–30 to 80

°

C with integral indicator

Relative humidity:

5% to 100% R.H. (at 40

°

C)

Preferred temperature and humidity:

approx. 25

°

C and 65% R.H.

(b) When storing the transmitter, repack it as nearly as

possible to the way it was packed when delivered
from the factory.

(c) If storing a transmitter that has been used, thor-

oughly clean the chambers inside the cover flanges,
so that no measured fluid remains in it. Also make
sure before storing that the pressure-detector and
transmitter section are securely mounted.