Component names, Component names -1 – Yokogawa EJA530A User Manual

Page 20

Advertising
background image

IM 01C21F01-01E

3-1

3. COMPONENT NAMES

3.

COMPONENT NAMES

Setting pin (CN4)

Integral
indicator

(Note 1)

CPU assembly

External indicator
conduit connection

(Note 1)

Transmitter section

Terminal box cover

Zero-adjustment screw

Pipe (Open to atmosphere)

(Note 3)

Capsule assembly

Mounting screw

Range-setting
switch

(Note 1)

(See Subsection 7.5)

Amplifier Cover

Setting Pin (CN4)
Position

(Note 2)

Burn-Out
Direction

Output at
Burn-Out

H

L

H

L

HIGH

LOW

110% or

higher

-5% or

lower

F0301.EPS

Note 1: See Subsection 10.2, “Model and Suffix Codes,” for

details.

Note 2: Insert the pin (CN4) as shown in the figure above to

set the burn-out direction. The pin is set to the H side
for delivery (unless option code /C1 is specified in the
order).
The setting can be confirmed by calling up parameter
D52 using the BRAIN TERMINAL. Refer to Subsection
8.3.3 (8).

Note 3: Applied to Model EJA530A with Measurement span

code A, B, and C.

Figure 3.1 Component Names

Table 3.1 Display Symbol

Display Symbol

%, Pa, kPa, MPa, kgf/cm

2

, gf/cm

2

, mbar, bar,

atm, mmHg, mmH

2

O, inH

2

O, inHg, ftH

2

O, psi, Torr

Meaning of Display Symbol

The output signal being zero-adjusted is increasing.

The output signal being zero-adjusted is decreasing.

Select one of these sixteen available engineering units for the display.

T0301.EPS