Yokogawa EJA530A User Manual

Page 58

Advertising
background image

IM 01C21F01-01E

10-2

10. GENERAL SPECIFICATIONS

EMC Conformity Standards “

”:

,

EN61326-1 Class A, Table 2 (For use in industrial

lications)

EN61326-2-3

Communication Requirements “

”:

BRAIN
Communication Distance;

Up to 2 km (1.25 miles) when using CEV polyethyl-
ene-insulated PVC-sheathed cables.
Communication distance varies depending on type
of cable used.

Load Capacitance;

0.22 µF or less (see note)

Load Inductance;

3.3 mH or less (see note)

Input Impedance of communicating device;

10 kΩ or more at 2.4 kHz.

Note: For general-use and Flameproof type.

For Intrinsically safe type, please refer to
‘Optional Specifications.’

HART
Communication Distance;

Up to 1.5 km (1 mile) when using multiple twisted
pair cables. Communication distance varies
depending on type of cable used.
Use the following formula to determine cable
length for specific applications:

L=

-

65 x 10

6

(R x C)

(C

f

+ 10,000)

C

Where:
L = length in meters or feet
R = resistance in Ω (including barrier resistance)
C = cable capacitance in pF/m or pF/ft
C

f

= maximum shunt capacitance of receiving

devices in pF/m or pF/ft

<Settings When Shipped> “

Tag Number

Output Mode

Display Mode

Operation Mode

Damping Time

Constant

As specified in order

*1

‘Linear’

‘2 sec.’

‘Normal’ unless otherwise specified in order

‘Linear’

Calibration Range

Units

As specified in order

As specified in order

Selected from mmH

2

O, mmAq, mmWG,

mmHg, Torr, Pa, hPa, kPa, MPa, mbar,
bar, gf/cm

2

, kgf/cm

2

, inH

2

O, inHg, ftH

2

O,

psi, or atm.(Only one unit can be specified)

Calibration Range

Higher Range Value

Calibration Range

Lower Range Value

T05E.EPS

Note 1: If Tag No. is no more than 16 alphanumeric characters (including - and ·), it will be written into

the tag plate and amplifier memory settings.

Physical Specifications

Wetted Parts Materials:

Diaphragm and Process connector;

See ‘Model and Suffix Codes.’

Non-wetted Parts Materials:

Housing;

Low copper cast-aluminum alloy with polyurethane
paint (Munsell 0.6GY3.1/2.0)

Degrees of Protection

IP67, NEMA4X, JIS C0920 immersion proof

Cover O-rings;

Buna-N

Data plate and tag;

SUS304 or SUS316 (optional)

Fill Fluid;

Silicone or Fluorinated oil (optional)

Weight:

1.6 kg (3.5 lb) without integral indicator and
mounting bracket.

Connections:

See ‘Model and Suffix Codes.’

Advertising