<3. Handling Cautions>

3-4

IM 01C25R01-01E

WARNING

Maintaining the safety of explosionproof

equipment requires great care during mounting,

wiring, and piping. Safety requirements also

place restrictions on maintenance and repair.

Please read the following sections very carefully.

WARNING

The range setting switch must not be used in a

hazardous area.

WARNING

Make sure to apply necessary protections on the

external temperature input cable, so as to avoid

damages leading to an earth fault.

IMPORTANT

All the blind plugs which accompany the EJX

transmitters upon shipment from the factory are

certified by the applicable agency in combination

with the EJX series transmitters. The plugs which

are marked with the symbols “◊ Ex” on their

surfaces are certified only in combination with

the EJX series transmitters.

3.9.1 FM Approval

a. FM Explosionproof Type
Caution for FM explosionproof type.

Note 1. EJX multivariable transmitter with optional

code /FF1 are applicable for use in

hazardous locations.

• Applicable Standard: FM3600, FM3615,

FM3810, ANSI/NEMA 250

• Explosionproof for Class I, Division 1,

Groups B, C and D.

• Dust-ignitionproof for Class II/III, Division 1,

Groups E, F and G.

• Enclosure rating: NEMA TYPE 4X.

• Temperature Class: T6

• Ambient Temperature: –40 to 60°C

• Power Supply:

42 V dc max. (HART Communication Type)

9 to 30 V dc, 250 mW (Modbus

Communication Type)

For F

OUNDATION

Fieldbus communication

type, refer to IM 01C25R03-01E.

• Output signal:

4 to 20 mA (HART Communication Type)

Modbus (Modbus Communication Type)

For F

OUNDATION

Fieldbus communication

type, refer to IM 01C25R03-01E.

Note 2. Wiring

• All wiring shall comply with National Electrical

Code ANSI/NFPA70 and Local Electrical

Codes.

• When installed in Division 1, “FACTORY

SEALED, CONDUIT SEAL NOT

REQUIRED.”

Note 3. Operation

• Keep the “WARNING” nameplate attached to

the transmitter.

WARNING: OPEN CIRCUIT BEFORE

REMOVING COVER. FACTORY SEALED,

CONDUIT SEAL NOT REQUIRED.

INSTALL IN ACCORDANCE WITH THE

USERS MANUAL IM 01C25.

• Take care not to generate mechanical

sparking when accessing to the instrument

and peripheral devices in a hazardous

location.

Note 4. Maintenance and Repair

• The instrument modification or parts

replacement by other than authorized

representative of Yokogawa Electric

Corporation is prohibited and will void

Factory Mutual Explosionproof Approval.

3.9.2 CSA Certification

a. CSA Explosionproof Type
Caution for CSA explosionproof type.

Note 1. EJX multivariable transmitter with optional

code /CF1 are applicable for use in

hazardous locations:

• Certificate: 2014354

• Applicable Standard:

C22.2 No.0, C22.2 No.0.4, C22.2 No.0.5,

C22.2 No.25, C22.2 No.30, C22.2 No.94,

C22.2 No.61010-1, C22.2 No.60079-0,

C22.2 No.60079-1

Advertising