<3. Handling Cautions>

3-6

IM 01C25R01-01E

3.9.3 ATEX Certification

ATEX Certification

(1) Technical Data

a. ATEX Flameproof Type

Caution for ATEX flameproof type.

Note 1. Model EJX Series pressure transmitters

with optional code /KF22 for potentially

explosive atmospheres:

• No. KEMA 07ATEX0109 X

• Applicable Standard: EN 60079-0:2009,

EN 60079-1:2007, EN 60079-31:2009

• Type of Protection and Marking Code:

Ex d IIC T6...T4 Gb, Ex tb IIIC T85°C Db

• Group: II

• Category: 2G, 2D

• Enclosure: IP66 / IP67

• Temperature Class for gas-poof:

T6, T5, and T4

• Ambient Temperature for gas-proof:

–50 to 75°C (T6), –50 to 80°C (T5), and

–50 to 75°C (T4)

• Maximum Process Temperature (Tp.) for

gas-proof:

85°C (T6), 100°C (T5), and 120°C (T4)

• Maximum Surface Temperature for dust-

proof:

T85°C (Tamb.: –30* to 75°C, Tp.: 85°C)

* –15°C when /HE is specified.

Note 2. Electrical Data

• Power Supply:

42 V dc max. (HART Communication Type)

9 to 30 V dc, 250 mW (Modbus

Communication Type)

• Output signal:

4 to 20 mA (HART Communication Type)

Modbus (Modbus Communication Type)

For F

OUNDATION

Fieldbus communication

type, refer to IM 01C25R03-01E.

Note 3. Installation

• All wiring shall comply with local installation

requirement.

• The cable entry devices shall be of a certified

flameproof type, suitable for the conditions of

use.

Note 4. Operation

• Keep the “WARNING” label attached to the

transmitter.

WARNING: AFTER DE-ENERGIZING,

DELAY 5 MINUTES BEFORE OPENING.

WHEN THE AMBIENT TEMP.≥65°C, USE

HEAT-RESISTING CABLE AND CABLE

GLAND ≥90°C.

• Take care not to generate mechanical

sparking when accessing to the instrument

and peripheral devices in a hazardous

location.

Note 5. Special Conditions for Safe Use

WARNING

• Electrostatic charge may cause an exlosion

hazard. Avoid any actions that cause the

gerenation of eletrostatic charge, such as

rubbing with a dry cloth on coating face of the

product.

• In the case where the enclosure of the

Pressure Transmitter is made of aluminium,

if it is mounted in an area where the use of

category 2D apparatus is required, it shall

be installed in such a way that the risk from

electrostatic discharges and propagating

brush discharges caused by rapid flow of

dust is avoided.

• The instrument modification or parts

replacement by other than an authorized

Representative of Yokogawa Electric

Corporation is prohibited and will void the

certification.

• To satisfy IP66 or IP67, apply waterproof

glands to the electrical connection port.

b. ATEX Intrinsically Safe Type
Caution for ATEX Intrinsically safe type.

Note 1. Model EJX Series Multivariable transmitter

with optional code /KS2 for potentially

explosive atmospheres:

• No. KEMA 06ATEX0037 X

• Applicable Standard: EN 50014:1997,

EN 50020:2002, EN 50284:1999,

EN 50281-1-1:1998

• Type of Protection and Marking code:

EEx ia IIC T4

• Group: II

• Category: 1G, 1D

Advertising